What our 112.5 kVA transformer buyers need to see
Start with a clear nameplate photo. For a 112.5 kVA unit, we need the manufacturer, phase count, primary and secondary voltages, frequency, winding material if listed, and manufacturing date. Include photos of the enclosure, terminals and any visible damage, plus a description of when and why the transformer came out of service.
We review operating units, unused surplus and failed transformers. Tell us about overheating, water exposure, damaged windings or missing components rather than describing every removed unit as working. Available test reports help us evaluate condition, but you can submit a unit for review without them.
To sell a 112.5 kVA transformer, send these basic details:
- Nameplate and overall photos, including terminal compartments where safely accessible.
- Current condition, service history and available test results.
- Pickup ZIP code, approximate dimensions and access restrictions.
- Fluid type and PCB information for an oil-filled unit.
Use our transformer offer form, or call or text 951-403-5738. We can review one transformer or multiple units from the same site.
Full-load amps for a 112.5 kVA transformer
| Voltage (line-to-line) | Full-load current |
|---|---|
| 208 V | 312.3 A |
| 480 V | 135.3 A |
| 600 V | 108.3 A |
| 4,160 V | 15.6 A |
| 12,470 V | 5.2 A |
| 13,200 V | 4.9 A |
| 13,800 V | 4.7 A |
| 34,500 V | 1.9 A |
Calculated as kVA × 1,000 ÷ (1.732 × V) for a three-phase unit. Check the nameplate for the actual ratings. Use the kVA to amps calculator.
Dry-type and padmount units at the 112.5 kVA rating
A 112.5 kVA rating is commonly encountered on three-phase dry-type distribution transformers. In New York buildings, these units often supply lighting, receptacles and other lower-voltage loads from a higher-voltage building distribution system. Renovations, tenant changes and electrical upgrades can leave them available for sale even when they remain usable.
We buy 112.5 kVA dry-type transformers from electrical rooms, commercial properties, institutional buildings and industrial facilities. Common configurations include 480 V primary to 208Y/120 V secondary and 600 V primary to 208Y/120 V secondary. Other voltage combinations exist, so send the actual nameplate rather than identifying a unit by enclosure appearance.
We also review liquid-filled padmount transformers labeled 112.5 kVA. Confirm the phase count and whether the rating applies to the complete assembly or an individual transformer in a bank. Medium-voltage primaries may include 4,160 V or utility distribution voltages such as 12,470 V and 13,200 V, with a secondary selected for the site's loads. Connection, taps and terminal arrangement matter alongside the voltage numbers.
112.5 kVA transformer full-load amps and voltage checks
The page's full-load amps table shows calculated current for a three-phase 112.5 kVA transformer at several line-to-line voltages. At 208 V, full-load current is 312.3 A; at 480 V, it is 135.3 A; and at 600 V, it is 108.3 A. These values describe different voltage sides or configurations, not three interchangeable ratings for the same terminals.
For three-phase equipment, the calculation is amps = kVA × 1,000 ÷ (√3 × line-to-line volts). Our kVA-to-amps calculator explains the relationship. Single-phase calculations use a different formula, so confirm the phase count before applying the table.
When we review a used 112.5 kVA transformer, we check the voltage combination, winding connection and available taps. A 208Y/120 V secondary provides a different connection arrangement from a delta secondary, even when another specification looks similar. Send a readable connection diagram if it appears on the nameplate. Calculated current alone is not a conductor or protective-device sizing instruction; confirm applicable installation requirements with the responsible electrical professional.

Approximate weight, oil volume and handling information
The weight of a 112.5 kVA transformer depends on its construction, enclosure, winding material and accessories. For preliminary planning, a dry-type unit may weigh roughly 600–1,200 pounds, while a liquid-filled padmount unit may be roughly 1,200–2,500 pounds. These are approximate ranges, and individual designs can fall outside them; check the nameplate and manufacturer documentation for the actual weight.
A liquid-filled unit at this rating may contain approximately 60–150 gallons of insulating fluid, depending on its tank and design. Check the nameplate for the actual fluid quantity and type. Do not use a general estimate to select lifting equipment or determine transport weight, especially if the listed weight excludes fluid or accessories.
Our transformer weight guide provides additional planning context. For your offer, include overall dimensions, marked lifting points and any known total weight. Tell us if the transformer is bolted down, mounted above floor level or located behind a narrow doorway. For fluid-filled units, include mineral oil, natural ester or silicone identification and any PCB labels or test records.
What affects resale value at 112.5 kVA
At this size, a usable voltage combination and documented condition are important parts of our review. An intact transformer with a readable nameplate, complete terminals and useful test information gives us more to evaluate for reuse. New surplus should be photographed with its crate, packaging and any storage damage clearly shown.
For a used unit, we consider age, winding material, enclosure condition, service history and signs of heat or moisture damage. Missing covers, cut leads, damaged bushings or an unreadable nameplate affect the assessment. Dry indoor storage is useful information, but it is not a substitute for electrical condition data.
Our guide to what a used transformer is worth explains the difference between reuse potential and material recovery. We also review failed and scrap units, with condition and recoverable materials guiding the offer. For liquid-filled transformers, fluid and PCB status affect handling and evaluation. Confirm current environmental requirements before draining, transporting or disposing of fluid; keep any existing documentation with the unit.
Pickup from New York electrical rooms and outdoor pads
We coordinate pickup across our New York service area, including sites where a 112.5 kVA transformer must move through a building before it reaches the truck. Tell us about stairs, elevators, loading docks, doorway widths and the route to the loading area. For an outdoor padmount, send photos showing truck access, ground conditions and nearby obstructions.
After reviewing the unit, we provide a written offer and agree on pickup and payment terms. We can coordinate rigging, forklift or crane handling and appropriate trucking, or you can load the unit if you prefer. Our buying and pickup process includes a quick inspection at pickup to confirm that the transformer matches the submitted photos and details.
Payment is by check, ACH or wire under the agreed terms. We have no public storefront or drop-off yard in New York; we come to the seller. Have qualified personnel disconnect and isolate equipment before handling. Confirm ownership before offering a unit: utility-owned transformers belong to the utility and cannot be sold by the property owner.
Questions sellers ask about 112.5 kVA
Who buys used 112.5 kVA transformers in New York?
We buy used 112.5 kVA electrical transformers anywhere in New York State, along with new surplus, decommissioned, damaged and scrap units. Send nameplate photos, overall condition photos and the pickup location. We review the specifications and condition, provide a written offer and coordinate pickup under agreed terms.
How many amps is a 112.5 kVA transformer at 208 volts?
For a three-phase 112.5 kVA transformer, calculated full-load current at 208 V line-to-line is 312.3 A. That calculation uses the transformer's apparent-power rating and voltage. Confirm the nameplate phase count and voltage before using the value; single-phase equipment requires a different calculation, and installation sizing requires additional checks.
How much does a 112.5 kVA transformer weigh?
As rough planning ranges, a dry-type unit may weigh about 600–1,200 pounds, and a liquid-filled padmount may weigh about 1,200–2,500 pounds. Designs vary and can fall outside those ranges. Check the nameplate or manufacturer documentation for actual weight, and confirm whether the figure includes insulating fluid before arranging lifting.
Can I sell a failed 112.5 kVA transformer without test reports?
Yes, we review failed and scrap 112.5 kVA transformers without requiring test reports to submit them. Explain the known failure and send photos of damage, terminals and the nameplate. For liquid-filled equipment, include available fluid and PCB information. We evaluate the unit's condition and recovery potential before making an offer.