225 kVA dry-type and padmount transformers in New York
A 225 kVA transformer may supply a commercial building’s distribution panels, a manufacturing area or a property’s three-phase service. In New York, indoor dry-type units commonly serve offices, retail spaces, warehouses and industrial facilities. Outdoor padmount units serve building loads from an enclosed, ground-level installation.
We buy 225 kVA dry-type transformers with ventilated enclosures and oil-filled padmount transformers, including used, decommissioned, damaged and scrap units. Tell us which form you have and whether it remains installed, has been disconnected or is already staged for loading. An enclosure photo helps us distinguish the construction before reviewing the nameplate.
We coordinate pickup throughout our New York service area, including sites with one transformer and facilities clearing multiple units. For a transformer beside a building or in a utility service area, confirm ownership before offering it. Utility-owned transformers belong to the utility and are not yours to sell simply because they sit on your property.
Full-load amps for a 225 kVA transformer
| Voltage (line-to-line) | Full-load current |
|---|---|
| 208 V | 624.5 A |
| 480 V | 270.6 A |
| 600 V | 216.5 A |
| 4,160 V | 31.2 A |
| 12,470 V | 10.4 A |
| 13,200 V | 9.8 A |
| 13,800 V | 9.4 A |
| 34,500 V | 3.8 A |
Calculated as kVA × 1,000 ÷ (1.732 × V) for a three-phase unit. Check the nameplate for the actual ratings. Use the kVA to amps calculator.
Common voltages and 225 kVA transformer full-load amps
A common three-phase dry-type arrangement is a 480 V primary with a 208Y/120 V secondary. Other units may have 600 V ratings or different winding configurations. For padmount equipment, primary ratings may include 12,470 V, 13,200 V or 13,800 V, with a 208Y/120 V or 480Y/277 V secondary. We need the actual nameplate ratings, not an estimate based on the building’s service voltage.
The full-load amps table on this page uses three-phase calculations and line-to-line voltage. At 225 kVA, the calculated current is 624.5 A at 208 V, 270.6 A at 480 V and 10.4 A at 12,470 V. These figures describe rated current at the listed voltage, not the transformer’s measured operating load.
Our kVA-to-amps calculator helps explain the relationship between capacity, voltage and current. For an offer, include primary and secondary voltage, phase, frequency, winding connection and available tap information. Single-phase calculations differ, so we confirm phase from the plate.
Approximate weight and oil volume at 225 kVA
For preliminary planning, the weight of a 225 kVA transformer may be approximately 1,000–2,500 pounds for a ventilated dry-type unit and 2,000–4,500 pounds for an oil-filled padmount unit. These are broad ranges, not lifting specifications. Enclosure design, winding material, tank construction and accessories affect the total; check the nameplate for the actual weight.
An oil-filled 225 kVA padmount may contain approximately 100–250 gallons of insulating fluid, depending on its design. Check the nameplate or fluid data plate for the quantity and fluid type. If that information is missing, send the model and serial number so we can identify what documentation is needed.
Our transformer weight guide provides additional planning context. For pickup, we use the documented weight and site conditions to coordinate handling equipment. Tell us about leaks, missing fluid or previous draining, and provide available PCB information. Confirm current handling and disposal requirements with the appropriate environmental professional; do not drain a transformer just to prepare it for sale.

What drives resale value for a used 225 kVA transformer
When you sell a 225 kVA transformer, we review its voltage combination, construction, age, condition and supporting records. A complete, usable unit with readable identification gives us more to evaluate than equipment with missing parts or an unknown failure history. We also consider whether its electrical configuration suits potential reuse.
Details that help us assess the unit include:
- Manufacturer, model, serial number and manufacture date, if shown.
- Primary and secondary ratings, taps, impedance and winding material, if documented.
- Clear photos of the enclosure, terminals, bushings and visible damage.
- Available test reports, maintenance records and the reason it was removed.
- For oil-filled units, fluid type, PCB status and any leak history.
Our guide to what a used transformer is worth explains these factors. We also review failed and scrap units based on their condition and recovery potential. If your replacement project includes a 300 kVA transformer, identify it separately rather than grouping different ratings under one description.
What 225 kVA transformer buyers need for a written offer
Start with a sharp photo of the complete nameplate and several photos showing the whole transformer. We need to read the rating fields and see the enclosure’s condition. For a padmount, include exterior photos and existing interior photos if available; do not open or approach energized compartments to obtain pictures.
Call or text 951-403-5738, or use our transformer offer form. Include your name, pickup location, quantity and whether the unit is operating, disconnected or already removed. Tell us if it is new surplus, used, decommissioned, damaged or being sold as scrap.
Describe access at the same time: basement, loading dock, outdoor pad, fenced yard or storage area. Note stairs, narrow doors, overhead restrictions and whether loading equipment is available. If you have test data or fluid records, send those with the photos. We review the equipment and logistics, then provide a written offer with agreed pickup and payment terms. Missing documentation is worth identifying upfront so we know which details still need confirmation.
How we coordinate pickup for a 225 kVA unit
A 225 kVA transformer requires a loading plan based on its documented weight, dimensions and location. We coordinate rigging, forklift or crane service and suitable flatbed, step-deck or lowboy trucking as needed. If you prefer to load the transformer with your own equipment, we can plan the pickup around that arrangement.
For an indoor dry-type unit, tell us how it will reach the loading area and whether doorways, elevators or dock access limit the move. For an outdoor padmount, identify truck access, ground conditions and any obstructions around the pad. Electrical disconnection must be handled by qualified personnel before removal; pickup is not a substitute for safely isolating the equipment.
Our buying and pickup process includes a quick inspection at pickup to confirm that the transformer matches the photos and agreed description. Payment is by check, ACH or wire under the agreed terms. We have no public storefront or drop-off yard in New York, so we come to the seller and coordinate collection at the site.
Questions sellers ask about 225 kVA
Who buys used 225 kVA transformers in New York?
We buy used 225 kVA electrical transformers anywhere in New York State, including dry-type and oil-filled padmount units. We also review new surplus, removed-from-service, damaged and scrap equipment. Send nameplate photos, condition details and the pickup location so we can evaluate the unit and provide a written offer.
How many amps is a 225 kVA transformer at 480 volts?
For a three-phase 225 kVA transformer, calculated full-load current at 480 V is 270.6 A. The calculation uses line-to-line voltage and assumes the full 225 kVA rating applies to that winding. We confirm voltage and phase from the nameplate when reviewing a unit; actual operating current depends on the connected load.
How much does a 225 kVA transformer weigh?
Broad planning ranges are approximately 1,000–2,500 pounds for a ventilated dry-type unit and 2,000–4,500 pounds for an oil-filled padmount. Check the nameplate for the actual weight, and use manufacturer documentation if it is not listed. We need documented weight and site access details to coordinate appropriate loading equipment.
Can I sell a failed 225 kVA transformer?
Yes, we review damaged, failed and scrap 225 kVA transformers as well as working units. Describe the failure, missing components, visible damage and any leaks, and send available test or fluid records. We assess the condition and recovery potential before making an offer. Keep the unit intact unless a safe handling plan requires otherwise.