Transformer Sizes

5000 kVA Transformer Buyers

After a service upgrade, plant closure or project redesign, you may need 5000 kVA transformer buyers for a large unit that is now surplus. We buy new-in-crate, used, removed-from-service, decommissioned and failed electrical transformers throughout New York State. A 5000 kVA unit is a 5 MVA transformer, so winding voltages, condition and loading access matter. Send us nameplate photos and site details so we can review it and arrange a written offer.

  • Written offers
  • Statewide pickup
  • One unit or a whole yard
Substation transformers in a snowy Western New York switchyard
Rating
5000 kVA / 5 MVA
Common forms
Three-phase liquid-filled padmount and substation
Common voltages
Primary: 12.47, 13.2, 13.8 or 34.5 kV; secondary: 480, 600 or 4160 V
FLA at a common voltage
6014.1 A at 480 V, three-phase calculated

5000 kVA Transformer Buyers for Padmount and Substation Units

We buy 5000 kVA transformers in padmount and substation configurations, including one surplus unit or multiple units from a facility shutdown. At this rating, three-phase liquid-filled equipment is common. We also review dry-type units when the rating, voltages and condition fit a reuse opportunity.

Large padmount transformers have enclosed cable compartments and are commonly installed outdoors on concrete pads. Substation transformers may have exposed bushings, enclosed terminals or connections to adjacent switchgear. Photos of both connection sides help us understand what is included and what has already been disconnected.

In New York, a 5 MVA transformer may serve a manufacturing plant, hospital campus, large commercial property or renewable-energy installation. We coordinate pickup across our New York service area, including sites where the transformer remains on its original pad. If the unit belongs to a utility, the property owner cannot sell it; confirm ownership before requesting an offer.

Full-load amps for a 5000 kVA transformer

Voltage (line-to-line)Full-load current
208 V13,878.6 A
480 V6,014.1 A
600 V4,811.3 A
4,160 V693.9 A
12,470 V231.5 A
13,200 V218.7 A
13,800 V209.2 A
34,500 V83.7 A

Calculated as kVA × 1,000 ÷ (1.732 × V) for a three-phase unit. Check the nameplate for the actual ratings. Use the kVA to amps calculator.

Voltage Ratings and Connections We Need to Review

Common primary ratings for this size include 12,470, 13,200, 13,800 and 34,500 volts. Secondary ratings may include 480, 600 or 4,160 volts, depending on the installation. A renewable-energy step-up transformer may use these voltage levels in the opposite power-flow direction, so send the complete nameplate rather than describing only the site service voltage.

We review the winding connections, frequency, impedance, taps and cooling designation along with the kVA rating. Delta and grounded-wye connections affect compatibility with a buyer’s system. A transformer with multiple cooling ratings needs a clear nameplate photo showing whether 5000 kVA is its base rating or a rating that depends on operating fans.

Include photos of bushings, cable compartments, tap controls and any attached cooling equipment. If your yard contains mixed ratings, our transformer size pages can help you separate the inventory before submitting it. List each unit individually rather than treating similar-looking tanks as identical equipment.

5000 kVA Transformer Full Load Amps

The full-load amps table on this page shows calculated three-phase current at several voltages. For a 5000 kVA transformer, the values include 480 V = 6014.1 A, 4160 V = 693.9 A and 13800 V = 209.2 A. These are winding-current calculations at the stated voltage, not measurements of the transformer’s actual operating load.

The three-phase calculation is rated VA divided by the square root of three times line-to-line voltage. Our kVA-to-amps calculator explains the relationship if you need to compare another voltage or rating.

We use the nameplate to confirm which table values apply to your unit. These calculations alone do not establish cable size, breaker settings or available fault current. Send existing drawings and test records if available, and have your electrical professional confirm installation requirements for any planned reuse.

Substation transformer with radiators loaded on a flatbed trailer
A substation transformer with radiators on the trailer.

Approximate Weight and Oil Volume for a 5 MVA Unit

The weight of a 5000 kVA transformer depends on its voltage class, tank design, windings, cooling equipment and fluid quantity. For preliminary planning, many liquid-filled padmount and substation units fall within an approximate total-weight range of 20,000–45,000 pounds, with roughly 800–2,000 gallons of insulating fluid. Units can fall outside these ranges; check the nameplate and manufacturer’s drawings for the actual weight and fluid quantity.

These estimates are not lift specifications. Confirm whether a listed weight includes fluid, radiators and accessories, and send any separate shipping-weight information. Our transformer weight guide explains why kVA alone is not enough to select lifting equipment.

Tell us whether the tank contains mineral oil, FR3/natural ester or silicone fluid, and report leaks or previous draining. Fluid condition and PCB status affect handling and the purchase review. Use available records or appropriate testing to establish PCB status; confirm current handling requirements before moving or draining equipment.

What Drives Resale Value at 5000 kVA

We evaluate a used 5000 kVA transformer by its electrical configuration, condition and practical reuse potential. A readable nameplate, useful voltage combination and documented operating history give us more information than exterior appearance alone. New surplus equipment should include photos of its crate, storage conditions and any shipping or factory-test documents.

Important factors include:

  • Primary and secondary voltages, winding connections, impedance and taps.
  • Age, cooling ratings and completeness of radiators, fans and controls.
  • Fluid type, PCB documentation, leaks and signs of moisture entry.
  • Available electrical tests and the reason it was removed from service.
  • Damage to bushings, terminals, tank walls or cable compartments.
  • Access and the work required to prepare it for loading.

We also buy failed and scrap units, but we review them differently from serviceable equipment. Tell us about faults, fire exposure or missing parts upfront. Our guide to used transformer value explains how condition and specifications shape an offer.

Send Photos and Records to Sell a 5000 kVA Transformer

To sell a 5000 kVA transformer, call or text 951-403-5738, or submit the details through our transformer offer form. Start with a sharp, straight-on nameplate photo, then include full views of the tank, connection compartments, radiators and any damage. Add the New York pickup location and tell us whether the transformer is disconnected, still installed or stored in a crate.

Include the quantity, condition, fluid type and PCB information. If available, send factory reports or recent results such as winding-resistance, insulation-resistance, turns-ratio and oil tests. We do not require you to energize or test a unit just to submit it for review.

For a failed transformer, describe what happened and what was removed afterward. For stored equipment, note how long it has been idle and how it was protected. We review the information and provide a written offer with the agreed purchase and payment terms.

Pickup Planning for Large Transformers in New York

A 5 MVA transformer needs a loading plan based on its actual weight, dimensions and location. We coordinate rigging, forklift or crane service, and flatbed, step-deck or lowboy trucking as appropriate. If you prefer to load the unit with your own equipment, we can coordinate that arrangement instead.

Send photos showing the route from the transformer to the truck position. Note gates, overhead lines, tight turns, sloped pavement, soft ground and nearby switchgear or cables that restrict access. Tell us about unloading or lifting drawings and any site scheduling restrictions before pickup is booked.

Have qualified personnel isolate and disconnect installed equipment before handling. We do not operate a public New York storefront or drop-off yard; we come to the seller through statewide pickup coordination. Our buying and pickup process includes a quick inspection at pickup to confirm the unit matches the submitted photos, followed by payment by check, ACH or wire under the agreed terms.

Questions sellers ask about 5000 kVA

Who buys used 5000 kVA transformers in New York?

We buy used 5000 kVA electrical transformers throughout New York State, including padmount and substation units removed during upgrades or shutdowns. We also review new surplus, decommissioned, damaged and failed units. Send the nameplate, condition photos, fluid information and pickup location so we can assess the transformer and provide a written offer.

How much does a 5000 kVA transformer weigh?

Many liquid-filled 5000 kVA units weigh approximately 20,000–45,000 pounds, but design and voltage class can put a transformer outside that range. Check the nameplate and manufacturer’s drawings for the actual total and shipping weights. We need documented weight and dimensions to coordinate suitable lifting equipment and trucking, not an estimate based only on kVA.

What are the full load amps of a 5000 kVA transformer?

Calculated three-phase full-load current depends on the winding voltage. At 480 V it is 6014.1 A; at 4160 V it is 693.9 A; and at 13800 V it is 209.2 A. Use the voltage and rating shown on the nameplate. These figures do not establish actual operating load or protection settings.

Can I sell a failed 5000 kVA transformer with oil still inside?

We buy failed and scrap transformers and can review units that still contain insulating fluid. Tell us the fluid type, known PCB status, leak condition and cause of failure, and send photos of the damage. Do not drain it solely for the sale inquiry; fluid handling and pickup arrangements should be agreed after review.

Send the nameplate. Get a written number.

Call or text 951-403-5738 with a photo of the nameplate and where the transformer sits. We buy transformers anywhere in New York and arrange the pickup.