As 10 MVA transformer buyers serving New York State, we buy new surplus, used, decommissioned, failed and scrap units. Send us nameplate photos, condition details and the pickup location so we can review your transformer and provide a written offer. At this size, voltage configuration, cooling ratings, test records and access for heavy hauling matter. We buy individual units or entire yards and coordinate pickup at the seller’s location.

  • Written offers
  • Statewide pickup
  • One unit or a whole yard
Substation transformers in a snowy Western New York switchyard
Rating
10 MVA / 10,000 kVA; confirm each cooling-stage rating on the nameplate.
Common forms
Oil-filled substation and power transformers, including generation step-up units.
Common voltages
Examples: 34.5 or 69 kV high side; 4.16, 12.47, 13.2 or 13.8 kV low side.
FLA at a common voltage
418.4 A at 13,800 V for a three-phase 10 MVA rating.

10 MVA transformer buyers for New York substation equipment

A 10 MVA transformer is rated at 10,000 kVA, but the complete nameplate tells us how that capacity is achieved. We review substation and power transformers with this rating, including units used for industrial distribution and generation step-up service. Oil-filled construction is common at this size, with external radiators and, on some designs, fans that support higher cooling-stage ratings.

In New York, equipment of this scale can serve manufacturing plants, large institutional campuses, utility substations and renewable-energy interconnections. We review transformers released through plant closures, electrical upgrades, project changes and replacement programs. For equipment integrated with adjacent switchgear, identify which components belong to the transformer and which remain on site.

Our substation transformer buying page covers that equipment category in more detail. We coordinate pickups across our New York service area, but sellers must establish ownership before offering a unit. Utility-owned transformers belong to the utility and cannot be sold by a property owner.

Full-load amps for a 10 MVA transformer

Voltage (line-to-line)Full-load current
208 V27,757.2 A
480 V12,028.1 A
600 V9,622.5 A
4,160 V1,387.9 A
12,470 V463 A
13,200 V437.4 A
13,800 V418.4 A
34,500 V167.3 A

Calculated as kVA × 1,000 ÷ (1.732 × V) for a three-phase unit. Check the nameplate for the actual ratings. Use the kVA to amps calculator.

Voltage ratings and 10 MVA transformer full-load amps

Common voltage configurations to send us include 34,500 V or 69,000 V on the high-voltage winding and 4,160 V, 12,470 V, 13,200 V or 13,800 V on the lower-voltage winding. These are examples, not a specification for every 10 MVA unit. Generation step-up equipment may operate with power flowing from the lower-voltage winding toward the grid-side winding.

For three-phase equipment, full-load current is calculated from apparent power and line-to-line voltage. The template’s 10 MVA transformer full-load amps table shows 1,387.9 A at 4,160 V, 418.4 A at 13,800 V and 167.3 A at 34,500 V. These values apply at the stated 10 MVA rating; use the actual nameplate rating for each winding and cooling stage.

Send clear photos of tap ranges, winding connections, impedance and cooling designations. A nameplate showing several MVA ratings needs more context than a single capacity figure. Our kVA-to-amps calculator explains the calculation, but calculated current alone is not enough to select cables, protective devices or replacement equipment.

Approximate weight and oil volume for a 10 MVA transformer

For early pickup planning, an oil-filled 10 MVA transformer may weigh approximately 30,000–80,000 pounds and contain roughly 1,500–4,000 gallons of insulating fluid. These are broad planning ranges, not lifting or transport specifications. Check the nameplate and manufacturer documentation for the actual total weight, shipping weight and oil quantity before arranging equipment.

The weight of a 10 MVA transformer depends on its voltage class, tank construction, core-and-coil design, radiators and installed accessories. Shipping weight may exclude oil or components that are removed for transport. Tell us exactly what remains attached and whether the stated weight describes a complete operating unit or a prepared shipping assembly.

Include photos of the dimensions plate, lifting points, base and radiators, plus any available outline drawing. Our transformer weight guide provides general context; the unit’s own records control the pickup plan. We also need to know whether the fluid is mineral oil, natural ester such as FR3, or silicone, and what documentation is available.

Row of used padmount transformers waiting for pickup in a yard
Used padmount transformers lined up for pickup.

What drives resale value for a used 10 MVA transformer

When we review a used 10 MVA transformer, we start with the voltage combination, capacity, condition and completeness. A reusable unit needs a configuration that fits another installation. Cooling equipment, bushings, tap-changing equipment and controls all affect that review, as do missing parts, leaks and physical damage.

Useful records include the manufacturing date, service history, removal date and reason for replacement. Send available electrical test reports and oil-analysis results, including dissolved gas analysis where available. Identify any known winding fault, overheating event, bushing failure or tank damage rather than describing a failed unit simply as used.

Fluid identity and PCB documentation also matter. Older oil-filled equipment needs a clear review of available records; confirm current handling and disposal requirements with qualified environmental professionals where needed.

We assess reusable equipment differently from failed or scrap units. For a scrap review, actual construction, remaining components and pickup costs matter. Our guide to what a used transformer is worth explains these factors without assigning a value from MVA alone.

What to send when you want to sell a 10 MVA transformer

To sell a 10 MVA transformer, call or text 951-403-5738 or submit our transformer offer form. Start with readable nameplate photos and wide views showing every side of the unit. For equipment still installed, include the surrounding access area so we can identify pickup constraints early.

Please send:

  • Manufacturer, serial number, year and all listed MVA ratings.
  • Primary and secondary voltages, taps, impedance and winding connections.
  • Condition, removal status and the reason it became available.
  • Fluid type, oil quantity and available PCB records.
  • Test reports, service records and a list of missing components.
  • Pickup address, dimensions, documented weight and loading access.

Tell us if the unit is new in its crate, stored outdoors, recently removed or damaged. For a multi-unit sale, label each photo set so we can match records to the correct transformer. We review the information and provide a written offer. Payment is by check, ACH or wire under the agreed terms; our buying process explains the steps.

Pickup planning for heavy 10 MVA units

A 10 MVA pickup starts with the transformer’s documented weight, transport dimensions and site access. We coordinate rigging, suitable forklift or crane equipment, and flatbed, step-deck or lowboy trucking according to the load. If your crew prefers to load the transformer, tell us what equipment is available and how loading will be handled.

We need details about gates, overhead clearance, pavement, slopes and the distance between the transformer and the truck position. Note any containment walls or adjacent switchgear that restrict access. If radiators, bushings or other components require removal for transport, that work and the resulting shipping configuration need to be agreed before pickup.

The transformer must be safely isolated and prepared by qualified personnel before loading. Heavy-haul routing and any required permits depend on the actual shipping dimensions and weight.

We have no public storefront or drop-off yard in New York; we come to the seller. At pickup, we perform a quick inspection to confirm the equipment matches the photos. If other ratings are included in the sale, identify them using our transformer size directory.

Questions sellers ask about 10 MVA

Who buys used 10 MVA transformers in New York?

We buy used 10 MVA transformers anywhere in New York State, along with surplus, decommissioned, damaged and scrap units. Send nameplate photos, condition details, available test records and the pickup location. We review the equipment, provide a written offer and coordinate pickup at your site rather than accepting public drop-offs.

What are the full-load amps of a 10 MVA transformer?

For a three-phase 10 MVA transformer, calculated full-load current is 418.4 A at 13,800 V and 167.3 A at 34,500 V. Current differs by winding voltage. We use the nameplate to confirm the actual voltage and capacity, including any separate ratings for different cooling stages.

How much does a 10 MVA transformer weigh?

An oil-filled 10 MVA transformer may weigh approximately 30,000–80,000 pounds, depending on its design, voltage class and accessories. Check the nameplate and manufacturer drawings for the actual weight. We also need to know whether that figure includes oil, radiators and bushings or represents a reduced shipping configuration.

Can I sell a failed 10 MVA transformer?

Yes, we review failed and damaged 10 MVA transformers as well as operating units. Describe the failure, identify missing components and send photos, fluid details and available PCB documentation. We assess the remaining equipment and pickup requirements before making a written offer; test records help us understand the unit’s condition.

Send the nameplate. Get a written number.

Call or text 951-403-5738 with a photo of the nameplate and where the transformer sits. We buy transformers anywhere in New York and arrange the pickup.