NEW YORK TRANSFORMER BUYERS 951-403-5738 Get an Offer

Transformer Sizes

Single-Phase 167 kVA Transformer Buyers

As 167 kVA transformer buyers, we purchase single-phase pole-mount and padmount units throughout New York State. We buy new surplus, used, removed-from-service, damaged and scrap transformers, individually or in groups. Send nameplate photos, condition details and the pickup location so we can review the equipment and provide a written offer. We coordinate pickup at your site, with payment by check, ACH or wire under the agreed terms.

  • Written offers
  • Statewide pickup
  • One unit or a whole yard
Close-up of a stainless-steel transformer nameplate on a green tank
Rating
167 kVA, single-phase
Common forms
Pole-mount and padmount
Common voltages
Primary: 7,200, 7,620, 14,400 or 19,920 V; secondary: 120/240 or 240/480 V; check the nameplate
FLA at a common voltage
695.8 A at 240 V, calculated single-phase full-load current

167 kVA Transformer Buyers: Forms and New York Applications

A single-phase 167 kVA transformer supplies a substantial single-phase load without being a three-phase transformer. We review both overhead pole-mount units and ground-mounted padmount units at this rating. The enclosure, primary connections, secondary arrangement and ownership matter when we evaluate equipment for purchase.

In New York, this size may serve larger residential loads, farm buildings, commercial properties or facilities with significant single-phase demand. Pole-mount units suit overhead distribution, while padmount units serve underground systems. Our padmount transformer buying page explains the details we review on enclosed, ground-mounted equipment.

We also review groups of single-phase transformers removed from a bank. Photograph each nameplate separately; matching tanks do not establish matching voltages, impedance or condition. Tell us whether the units operated together or came from different locations.

We coordinate purchases across our New York service area, including properties on Long Island. Confirm ownership before requesting an offer: a utility-owned transformer belongs to the utility and is not yours to sell merely because it sits on your property.

Full-load amps for a Single-Phase 167 kVA transformer

Voltage (single-phase)Full-load current
120 V1,391.7 A
240 V695.8 A

Calculated as kVA × 1,000 ÷ V for a single-phase unit. Check the nameplate for the actual ratings. Use the kVA to amps calculator.

Primary Voltages, Secondary Voltages and Full-Load Amps

Common single-phase distribution primary ratings include approximately 7,200, 7,620, 14,400 and 19,920 volts, depending on the system and winding connection. Common secondary arrangements include 120/240 volts and, for some applications, 240/480 volts. Check the nameplate for the actual winding ratings, taps and connection diagram rather than identifying voltage from the tank or bushings.

A feeder's stated system voltage may differ from the transformer's primary winding voltage. For example, a single-phase transformer connected phase-to-neutral on a grounded-wye system sees the phase-to-neutral voltage. Send a clear connection-diagram photo so we can review the unit accurately.

The template's 167 kVA transformer full-load amps table shows 120 V = 1391.7 A and 240 V = 695.8 A. These calculated values use single-phase current equal to VA divided by volts; our kVA-to-amps calculator explains that relationship.

For a center-tapped 120/240-volt secondary, the 120-volt table entry is not the allowable current on each leg. With the full rating distributed evenly, each 120-volt half carries approximately 695.8 A. Actual loading must follow the nameplate and winding configuration.

Approximate Weight and Oil Volume at 167 kVA

The weight of a 167 kVA transformer depends on its tank, core, windings, fluid quantity and enclosure. For preliminary handling discussions, an oil-filled pole-mount unit may weigh approximately 1,200–2,500 pounds, while a padmount unit may weigh approximately 1,800–3,500 pounds. These are broad planning ranges, not lifting specifications; check the nameplate for the actual total weight.

Approximate fluid quantities may fall around 50–120 gallons for a pole-mount unit and 70–160 gallons for a padmount unit. Construction varies, and units can fall outside these ranges. Check the nameplate for oil volume and fluid identification, and send any separate fluid label if the main plate omits that information.

Our transformer weight guide provides additional handling context. We still need unit-specific information before arranging a forklift, crane or truck.

Tell us whether the transformer remains full, has been drained or has a visible leak. Do not drain it solely to prepare it for sale. Provide available fluid and PCB records, and confirm current handling requirements with the appropriate professionals if documentation is missing.

Padmount transformers staged next to a crane for loading
Padmounts set out for crane loading.

What Drives a Used 167 kVA Transformer's Resale Value

We evaluate a used 167 kVA transformer by its electrical configuration, condition and suitability for another installation. A readable nameplate helps us establish the rating and voltage combination. Clear photos of bushings, terminals, the tank and the padmount cabinet help us identify damage and missing components.

The main details we review include:

  • Primary and secondary voltages, tap settings and connection diagram.
  • Manufacturer, age and available service history.
  • Whether the unit was working when removed, failed in service or never installed.
  • Fluid type, PCB documentation, leaks and tank condition.
  • Available electrical test results and the completeness of included parts.

New-in-crate equipment needs photos of both the crate and nameplate, plus details about storage and any packaging damage. For removed units, tell us the removal reason and whether they have been stored upright and protected from damage.

We consider damaged and scrap units as well as reusable equipment. Our guide to what a used transformer is worth explains the distinction between reuse potential and material recovery. We provide a written offer after reviewing the specific unit; capacity alone is not enough to establish its value.

Pickup Planning for Pole-Mount and Padmount Units

We coordinate pickup at the seller's location; we do not operate a public New York storefront or drop-off yard. At this size, loading arrangements depend on the actual weight, lifting provisions and access around the transformer. We can coordinate rigging, forklift or crane service and suitable trucking, or you can load with your equipment if agreed in advance.

For a pole-mount unit, tell us whether it is still installed overhead or already on the ground. Qualified personnel must de-energize, disconnect and safely remove installed equipment before loading. For a padmount unit, show us the cabinet, pad, access route and any fence or barrier that limits equipment movement.

Useful pickup photos include the transformer from several sides, its lifting points and the route to the truck position. Note soft ground, narrow gates, overhead obstructions and restricted delivery hours. These details help us plan handling rather than discover access problems at loading.

Our buying and pickup process includes a brief inspection at pickup to confirm the equipment matches the submitted photos. Payment follows the agreed terms, so we establish those terms before scheduling the move.

Send the Details Needed for a Written Offer

To sell a 167 kVA transformer, call or text 951-403-5738, or submit our transformer offer form. Start with a readable nameplate photo and wide photos showing the complete unit. If you have several transformers, identify each one so we can connect its plate, condition and location details.

Include the information you have:

  • Quantity, single-phase rating and pole-mount or padmount construction.
  • Primary and secondary voltages, age and current condition.
  • Fluid identification, PCB status and available test reports.
  • Whether each unit is installed, disconnected, crated or stored outdoors.
  • Pickup town, site access and available loading equipment.

Photograph damaged bushings, rust, leaks or missing cabinet parts directly. Accurate condition information lets us evaluate reusable equipment and scrap units on the right basis. If records are incomplete, tell us what is missing instead of guessing at fluid status or service history.

We review the submission, provide a written offer and agree on loading and payment arrangements. You do not need to transport the unit to us for an initial review.

Questions sellers ask about Single-Phase 167 kVA

Who buys used 167 kVA transformers in New York?

We buy used single-phase 167 kVA pole-mount and padmount transformers throughout New York State. We also review new surplus, removed-from-service, failed and scrap units. Send nameplate photos, condition details and the pickup location for a written offer. We coordinate pickup rather than accepting public yard drop-offs.

What are the full-load amps of a 167 kVA transformer?

Calculated single-phase full-load current is 1391.7 A at 120 volts and 695.8 A at 240 volts. A center-tapped 120/240-volt transformer requires attention to the winding arrangement: the 120-volt calculation is not a per-leg rating. Check the nameplate and connection diagram before using these figures for load planning.

How much does a single-phase 167 kVA transformer weigh?

Broad approximate planning ranges are 1,200–2,500 pounds for oil-filled pole-mount units and 1,800–3,500 pounds for padmount units. Actual weight varies with construction, fluid and enclosure, and may fall outside those ranges. Check the nameplate; we use unit-specific weight and lifting information to coordinate loading.

Can I sell a failed or leaking 167 kVA transformer?

We review failed, damaged and scrap 167 kVA transformers as well as working units. Send photos of the damage, describe the failure and include available fluid and PCB records. Report any leak before pickup planning. Do not drain or move a leaking unit just to prepare it for our review.

Send the nameplate. Get a written number.

Call or text 951-403-5738 with a photo of the nameplate and where the transformer sits. We buy transformers anywhere in New York and arrange the pickup.

Call 951-403-5738